水研环境 Water-Research Environment

NF

Nanofiltration elements

Spiral-wound nanofiltration in three published series: SY-NF30, SY-NF60, and SY-NF90. For softening, partial desalting, and reuse trains after a suitable pretreatment.

Membrane skid RO-01 in a Shuiyan plant room

SY-NF30 performance

SY-NF30 performance
ModelAverage fluxStable desalinationEffective areaFeed screen
SY-NF30-40401,900 GPD95%85 ft² (8 m²)31 mil
SY-NF30-8040(400)9,000 GPD95%400 ft² (37 m²)31 mil

Test: 25°C (77°F), 2,000 ppm MgSO₄, 70 psi (0.48 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%.

SY-NF30 maximum operating values

SY-NF30 maximum operating values
LimitValueLimitValue
Maximum operating pressure365 psi (2.5 MPa)Feed pH, continuous3–10
Maximum feed temperature113°F (45°C)Feed pH during chemical cleaning2–12
Maximum feed SDI5Maximum pressure drop per element15 psi (0.1 MPa)
Maximum residual chlorine<0.1 ppm

SY-NF60 performance

SY-NF60 performance
ModelAverage fluxStable desalinationEffective areaFeed screen
SY-NF60-40401,800 GPD97%85 ft² (8 m²)31 mil
SY-NF60-8040(400)8,000 GPD97%400 ft² (37 m²)31 mil
SY-NF60-4040FR1,900 GPD97%82 ft² (7.6 m²)34 mil
SY-NF60-8040FR(400)8,000 GPD97%400 ft² (37 m²)34 mil

Test: 25°C (77°F), 2,000 ppm MgSO₄, 70 psi (0.48 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%.

SY-NF60 maximum operating values

SY-NF60 maximum operating values
LimitValueLimitValue
Maximum operating pressure365 psi (2.5 MPa)Feed pH, continuous3–10
Maximum feed temperature113°F (45°C)Feed pH during chemical cleaning2–12
Maximum feed SDI5Maximum pressure drop per element15 psi (0.1 MPa)
Maximum residual chlorine<0.1 ppm

SY-NF90 performance

SY-NF90 performance
ModelAverage fluxStable desalinationEffective areaFeed screen
SY-NF90-40401,800 GPD98.5%85 ft² (8 m²)28 mil
SY-NF90-8040(400)7,000 GPD98.5%400 ft² (37 m²)28 mil
SY-NF90-8040(440)7,700 GPD98.5%440 ft² (41 m²)28 mil

Test: 25°C (77°F), 2,000 ppm MgSO₄, 70 psi (0.48 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%.

SY-NF90 maximum operating values

SY-NF90 maximum operating values
LimitValueLimitValue
Maximum operating pressure365 psi (2.5 MPa)Feed pH, continuous3–10
Maximum feed temperature113°F (45°C)Feed pH during chemical cleaning2–12
Maximum feed SDI5Maximum pressure drop per element15 psi (0.1 MPa)
Maximum residual chlorine<0.1 ppm

How the series is used

  • Typical duties named for this part of the catalogue are brackish polishing, industrial reuse, and a step ahead of reverse osmosis where hardness or organics should come down first.
  • Pretreatment is part of the design. An NF element is not offered against an unknown silt density or an unknown residual oxidant.
  • Each series has its own model table. A quotation names the element, the test condition, and the recovery assumed for your water.

What to send with the quotation

  • Wastewater type and any discharge or reuse standard you must meet.
  • Design capacity in m³/d, and whether the flow is steady or seasonal.
  • Temperature, suspended solids, and, for NF or RO, salinity.
  • Whether you need modules only, a packaged plant, or a system package with commissioning.
Request a technical quotation