RO
Reverse osmosis elements
Three RO families in the 2025 manual: seawater SY-SW, brackish SY-BW, and ultra-low-pressure SY-ULP. Each family has its own model table.

SY-SW seawater elements
| Model | Average flux | Stable desalination | Effective area | Feed screen |
|---|---|---|---|---|
| SY-SW4040-HR | 1,450 GPD | 99.8% | 85 ft² (8 m²) | 28 mil |
| SY-SW8040-HF(400) | 9,000 GPD | 99.8% | 400 ft² (37 m²) | 34 mil |
| SY-SW8040-HF(440) | 9,900 GPD | 99.8% | 440 ft² (41 m²) | 28 mil |
| SY-SW8040-HR(400) | 7,000 GPD | 99.8% | 400 ft² (37 m²) | 34 mil |
| SY-SW8040-HR(440) | 7,700 GPD | 99.8% | 440 ft² (41 m²) | 28 mil |
| SY-SW8040-HPZ(400) | 8,500 GPD | 99.7% | 400 ft² (37 m²) | 34 mil |
Test: 25°C (77°F), 32,000 ppm NaCl, 800 psi (5.52 MPa), recovery 8%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%.
SY-SW maximum operating values
| Limit | Value | Limit | Value |
|---|---|---|---|
| Maximum operating pressure | 1,200 psi (8.3 MPa) | Feed pH, continuous | 2–11 |
| Maximum feed temperature | 113°F (45°C) | Feed pH during chemical cleaning | 1–13 |
| Maximum feed SDI | 5 | Maximum pressure drop per element | 15 psi (0.1 MPa) |
| Maximum residual chlorine | <0.1 ppm |
SY-BW brackish-water elements
| Model | Average flux | Stable desalination | Effective area | Feed screen |
|---|---|---|---|---|
| SY-BW4040-LP | 2,400 GPD | 99.5% | 85 ft² (8 m²) | 31 mil |
| SY-BW4040-CHR | 2,400 GPD | 99.2% | 85 ft² (8 m²) | 31 mil |
| SY-BW8040-LP(400) | 10,500 GPD | 99.5% | 400 ft² (37 m²) | 31 mil |
| SY-BW8040-LP(440) | 11,500 GPD | 99.5% | 440 ft² (41 m²) | 28 mil |
| SY-BW8040-FR(400) | 11,000 GPD | 99.7% | 440 ft² (41 m²) | 34 mil |
| SY-BW8040-FRB(400) | 10,500 GPD | 99.2% | 400 ft² (37 m²) | 34 mil |
| SY-BW8040-FRZ(400) | 10,500 GPD | 99.7% | 400 ft² (37 m²) | 34 mil |
Test: 25°C (77°F), 2,000 ppm NaCl, 225 psi (1.55 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%. Stated duty: surface water and brackish water with TDS below 8,000 ppm.
SY-BW maximum operating values
| Limit | Value | Limit | Value |
|---|---|---|---|
| Maximum operating pressure | 600 psi (4.1 MPa) | Feed pH, continuous | 2–11 |
| Maximum feed temperature | 113°F (45°C) | Feed pH during chemical cleaning | 1–13 |
| Maximum feed SDI | 5 | Maximum pressure drop per element | 15 psi (0.1 MPa) |
| Maximum residual chlorine | <0.1 ppm |
SY-ULP low-pressure elements
| Model | Average flux | Stable desalination | Effective area | Feed screen |
|---|---|---|---|---|
| SY-ULP4040-FR | 2,600 GPD | 99.5% | 85 ft² (8 m²) | 28 mil |
| SY-ULP4040-CHR | 2,600 GPD | 99.0% | 76 ft² (7.2 m²) | 34 mil |
| SY-ULP4040-LHF | 2,600 GPD | 99.0% | 76 ft² (7.2 m²) | 34 mil |
| SY-ULP8040-FR(400) | 10,500 GPD | 99.5% | 400 ft² (37 m²) | 34 mil |
| SY-ULP8040-FR(440) | 11,500 GPD | 99.5% | 440 ft² (41 m²) | 28 mil |
| SY-ULP8040-CHR(400) | 10,500 GPD | 99.0% | 400 ft² (37 m²) | 34 mil |
Test: 25°C (77°F), 1,500 ppm NaCl, 150 psi (1.03 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%. Stated duty: feed TDS below 2,000 ppm. The manual cites high water production at an operating pressure of 10 kg.
SY-ULP maximum operating values
| Limit | Value | Limit | Value |
|---|---|---|---|
| Maximum operating pressure | 600 psi (4.1 MPa) | Feed pH, continuous | 2–11 |
| Maximum feed temperature | 113°F (45°C) | Feed pH during chemical cleaning | 1–13 |
| Maximum feed SDI | 5 | Maximum pressure drop per element | 15 psi (0.1 MPa) |
| Maximum residual chlorine | <0.1 ppm |
How the series is used
- Duties include brackish desalting, seawater duty where SY-SW is the right series, industrial pure water, tertiary reuse, and a membrane step inside a zero-liquid-discharge train when the water justifies it.
- Recovery, flux, and rejection are properties of a model at a stated test condition. They are not given as a single catalogue promise.
- UF or another pretreatment is selected with the element. Send salinity, temperature, and the required permeate quality.
What to send with the quotation
- Wastewater type and any discharge or reuse standard you must meet.
- Design capacity in m³/d, and whether the flow is steady or seasonal.
- Temperature, suspended solids, and, for NF or RO, salinity.
- Whether you need modules only, a packaged plant, or a system package with commissioning.