Reinforced hollow-fiber ultrafiltration
Hollow-fiber UF modules for clarification, pretreatment, and tertiary duty. External and submerged series are both in the 2025 manual, with operating and CIP tables.

Reinforced hollow-fiber UF — operating parameters
| Item | Published value |
|---|---|
| Typical flux, municipal wastewater (good biodegradability) | 18–25 LMH |
| Typical flux, industrial wastewater (good biodegradability) | 15–18 LMH |
| Typical flux, general industrial wastewater | 12–15 LMH |
| Typical flux, poor biodegradability | 8–12 LMH |
| TMP range | 0–35 kPa |
| Maximum TMP during filtration | 35 kPa |
| Tolerable sludge concentration | 5,000–12,000 mg/L |
| Operating mode | 7 min on, 1 min off |
| Air scouring intensity | 80–120 Nm³/(m²·h) |
| Operating temperature | 10–35°C |
| Maintenance sodium hypochlorite wash | Once a week, low concentration |
| Maintenance cleaning duration | 30–60 min |
| Maintenance cleaning flow | 2–4 L per m² of membrane |
| Maintenance hypochlorite concentration | 500–800 ppm |
| Restorative cleaning | Hypochlorite wash monthly; acid wash at least every six months |
| Restorative duration | 2–6 h |
| Restorative hypochlorite | 1,000–3,000 ppm |
| Restorative citric or oxalic acid | 1–2% by mass |
| Offline cleaning | When online cleaning does not restore TMP, or TMP exceeds 35 kPa |
| Offline duration | 1–2 days |
| Offline hypochlorite | 3,000 ppm |
| Offline citric or oxalic acid | 1–2% by mass |
Average pore size is less than 0.02 μm. The manual states bacterial removal above 99.99%, and that the product has passed NSF (National Sanitation Foundation) product testing and certification and holds the relevant health permits. No certificate number is printed in the manual. Adjust cleaning to the water and the process.
External UF modules SY-UF
| SY-UF-40 | SY-UF-60 | SY-UF-70 | |
|---|---|---|---|
| Average pore size | 0.02 μm | 0.02 μm | 0.02 μm |
| Membrane area | 40 m² | 60 m² | 70 m² |
| Fiber inner / outer diameter | 0.7 / 1.3 mm | 0.7 / 1.3 mm | 0.7 / 1.3 mm |
| Effective fiber length | 1,600 mm | 1,600 mm | 1,600 mm |
| Module dimensions | Φ60 × 2,209 mm | Φ225 × 2,168 mm | Φ238 × 2,128 mm |
| Membrane fiber | PVDF | PVDF | PVDF |
| Sealing compound | Epoxy resin | Epoxy resin | Epoxy resin |
| Housing | UPVC | UPVC | UPVC |
| Maximum inlet pressure | 0.30 MPa | 0.30 MPa | 0.30 MPa |
| Operating temperature | 5–40°C | 5–40°C | 5–40°C |
| pH range | 2–12 | 2–12 | 2–12 |
| Maximum inlet turbidity | 300 NTU | 300 NTU | 300 NTU |
| Treated-water turbidity | ≤0.1 NTU | ≤0.1 NTU | ≤0.1 NTU |
| Operating mode | Cross-flow or dead-end | Cross-flow or dead-end | Cross-flow or dead-end |
The same model can be assembled with a different module count.
External UF — design and cleaning
| Item | Published value |
|---|---|
| Typical flux | 50–100 LMH |
| TMP range | 30–150 kPa |
| Maximum TMP during filtration | 200 kPa |
| Maximum feed water pressure | 300 kPa |
| Cross-flow recirculation | 10–30% |
| Backwash method | Air-water backwash |
| Design backwash frequency | 48 times/day |
| Backwash air pressure | ≤150 kPa |
| Backwash gas flow | 8–12 Nm³/h |
| Backwash water flow | 0.5–1.5 times product water flux |
| Backwash interval | 30–60 min |
| Maintenance chemical | Circulating rinse, low-concentration citric acid or sodium hypochlorite |
| Maintenance duration | 50 min |
| Maintenance frequency | 1–3 days per set |
| Maintenance citric-acid frequency | 1–3 days per set |
| Maintenance flow | 1–2 m³ per module |
| Maintenance concentration | 300–500 ppm |
| Restorative method | Circulating rinse, high-concentration citric acid and sodium hypochlorite |
| Restorative duration | 90–120 min |
| Restorative frequency | 30–90 days per cycle |
| Restorative flow | 1–3 m³ per module |
| Restorative concentration | 1,000–3,000 ppm |
Immersed UF modules SY-SUF
| SY-SUF-17 | SY-SUF-22 | SY-SUF-32 | |
|---|---|---|---|
| Average pore size | 0.02 μm | 0.02 μm | 0.02 μm |
| Membrane area | 17 m² | 22 m² | 32 m² |
| Fiber inner / outer diameter | 1.6 / 2.0 mm | 1.6 / 2.0 mm | 1.0 / 2.0 mm |
| Overall dimensions | 535 × 40 × 1,500 mm | 535 × 40 × 2,000 mm | 844 × 49 × 2,091 mm |
| Membrane fiber | PVDF | PVDF | PVDF |
| Encapsulant | Epoxy resin | Epoxy resin | Epoxy resin |
| Configuration | Submerged | Submerged | Submerged |
| Filtration direction | Outside-in | Outside-in | Outside-in |
| Maximum suction pressure | 65 kPa | 65 kPa | 65 kPa |
| Maximum operating temperature | 40°C | 40°C | 40°C |
| pH range | 2–12 | 2–12 | 2–12 |
| Turbidity of treated water | <0.1 NTU | <0.1 NTU | <0.1 NTU |
Design flux is set from water temperature and water quality. Fiber tensile strength is stated as above 100 N.
Immersed UF — design and cleaning
| Item | Published value |
|---|---|
| Typical flux | 20–60 LMH |
| TMP range | 0–65 kPa |
| Maximum TMP during filtration | 65 kPa |
| Water recovery | >95% |
| Permeate turbidity | <0.1 NTU |
| Backwash method | Air-water backwash |
| Design backwash frequency | 60–120 min/cycle |
| Backwash gas flow | 4.5–6 Nm³/h per module |
| Backwash water flow | 1–2 times the permeate flux |
| Backwash operation | 55–115 min, then air-water backwash for 1–2 min, drain and air purge for 1 min |
| Maintenance hypochlorite frequency | Every 1–5 days |
| Maintenance flow | 44–88 L per cycle per module |
| Maintenance concentration | 300–1,000 ppm |
| Maintenance method | Soaking, circulation, aeration |
| Maintenance duration | 2–4 hours, including chemical injection and drainage |
| Acid or citric cleaning | Every 7–30 days |
| Hypochlorite restorative frequency | Every 7–30 days |
| Minimum chemical volume | Enough to submerge the modules |
| Restorative concentration | Hydrochloric acid, pH 2; citric acid 0.5–1%; sodium hypochlorite 500–1,500 ppm |
| Offline cleaning | 1–2 times per year, 1–10 h |
| Offline chemicals | Hydrochloric acid pH 2; citric acid 1–2%; sodium hypochlorite 3,000–5,000 ppm |
How the series is used
- Duties include surface-water and groundwater clarification, pretreatment ahead of ion exchange or reverse osmosis, and tertiary polishing.
- The manual prints operating limits and a CIP table for this section. Those limits are quoted with the model, not averaged across the catalogue.
- Send turbidity or suspended solids, temperature, and the downstream membrane if this UF is a pretreatment.
What to send with the quotation
- Wastewater type and any discharge or reuse standard you must meet.
- Design capacity in m³/d, and whether the flow is steady or seasonal.
- Temperature, suspended solids, and, for NF or RO, salinity.
- Whether you need modules only, a packaged plant, or a system package with commissioning.